M5CCWS030CR/M5WSS030AR
Cooling Only/ Cooling Mode (Heatpump)
Water Flow Rate = 1.08 m
3
/hr
Water Flow Rate = 1.80 m
3
/hr
Water Flow Rate = 2.52 m
3
/hr
Indoor, DB Indoor, WB Capacity
(°C) (°C) (kW) 13 20 25 30 35 40 45
TC 8.86 8.48 8.20 7.93 7.49 7.06 6.62
SC
8.67 8.32 8.06 7.81 7.41 7.01 6.61
TC 9.19 8.78 8.49 8.20 7.71 7.22 6.74
SC 7.94 7.68 7.49 7.30 7.00 6.71 6.42
TC
9.64 9.19 8.87 8.55 8.00 7.45 6.90
SC 6.98 6.82 6.71 6.50 6.45 6.29 6.15
TC
9.74 9.35 9.06 8.78 8.26 7.74 7.22
SC 6.40 6.25 6.15 6.05 5.90 5.76 5.63
TC
10.07 9.82 9.64 9.46 9.03 8.61 8.19
SC 4.72 4.63 4.56 4.49 4.37 4.25 4.13
TC 10.18 9.97 9.83 9.68 9.29 8.91 8.52
SC
4.18 4.11 4.05 4.00 3.88 3.77 3.65
Indoor, DB Indoor, WB Capacity
(°C) (°C) (kW) 13 20 25 30 35 40 45
TC 9.26 8.86 8.58 8.29 7.84 7.38 6.92
SC 9.06 8.70 8.43 8.17 7.75 7.33 6.91
TC
9.61 9.18 8.88 8.57 8.06 7.55 7.05
SC 8.31 8.03 7.83 7.64 7.32 7.01 6.71
TC
10.08 9.61 9.27 8.94 8.36 7.79 7.21
SC 7.30 7.13 7.01 6.79 6.74 6.58 6.43
TC 10.19 9.77 9.47 9.18 8.63 8.09 7.55
SC 6.69 6.54 6.43 6.33 6.17 6.03 5.89
TC 10.53 10.26 10.08 9.89 9.45 9.01 8.57
SC
4.94 4.84 4.77 4.70 4.57 4.44 4.32
TC 10.64 10.43 10.28 10.12 9.72 9.31 8.91
SC
4.37 4.29 4.24 4.18 4.06 3.94 3.82
Indoor, DB Indoor, WB Capacity
(°C) (°C) (kW) 13 20 30 35 40 45
TC
9.46 9.06 8.76 8.47 8.01 7.54 7.07
SC 9.26 8.88 8.62 8.35 7.92 7.49 7.06
TC
9.82 9.38 9.07 8.76 8.24 7.72 7.20
SC 8.49 8.20 8.00 7.80 7.48 7.17 6.85
TC 10.29 9.82 9.47 9.13 8.54 7.96 7.37
SC 7.46 7.28 7.17 6.94 6.89 6.72 6.57
TC 10.41 9.98 9.68 9.37 8.82 8.27 7.71
SC
6.84 6.68 6.57 6.46 6.31 6.16 6.02
TC 10.76 10.49 10.29 10.10 9.65 9.20 8.75
SC
5.04 4.94 4.87 4.80 4.67 4.54 4.42
TC 10.87 10.65 10.50 10.34 9.93 9.51 9.10
SC 4.46 4.39 4.33 4.27 4.15 4.02 3.90
23
24
15.5
17
19
20
Entering Water Temperature, (°C)
27.0
15.5
17
19
20
23
24
15.5
17
Entering Water Temperature, (°C)
27.0
Entering Water Temperature, (°C)
27.0
19
20
23
24
Note:
1. DB = Dry Bulb, WB = Wet Bulb, TC = Total Capacity, SC = Sensible Capacity
2. All datas above are generated at delta T = Leaving Water Temperature - Entering Water Temperature = 5