Installation, Operation and Maintenance Manual IOMM ACR/AGR-1
Group: Chiller
Part Number: 074644201
Effective: March 2000
Supersedes: IOMM ACR/AGR
© 1997 McQuay International
AIR-COOLED, RECIPROCATING, SPLIT SYSTEMS
Chiller w/ Remote Evaporator, AGR 070AM-100AM
Condensing Unit, ACR 060AS-120AS
DX Evaporators, CDE
60 Hertz, R-22
Global Chiller Line
Page view 0
1 2 3 4 5 6 ... 103 104

Summary of Contents

Page 1 - DX Evaporators, CDE

Installation, Operation and Maintenance Manual IOMM ACR/AGR-1Group: ChillerPart Number: 074644201Effective: March 2000Supersedes: IOMM ACR/AGR© 1997 M

Page 2 - Table of Contents

10 IOMM ACR/AGR-1Table 5, Flow Switch Minimum Flow RatesNOMINAL PIPE SIZEINCHES (mm)MINIMUM REQUIRED FLOW TOACTIVATE SWITCH - gpm (L/s)1 (25.4) 6.00

Page 3 - Introduction

100 IOMM ACR/AGR-1EvaporatorThe remote evaporator on AGR-AM units and CDE evaporators are the direct expansion, shell-and-tube type with refrigerant f

Page 4 - Installation

IOMM ACR/AGR-1 1012. Add the charge to the system through the suction shutoff valve or through the Schrader fitting onthe tube entering the evaporator

Page 5 - Service Access

102 IOMM ACR/AGR-1AGR Troubleshooting ChartPROBLEM POSSIBLE CAUSES POSSIBLE CORRECTIVE STEPS1. Main Switch. 1. Close Switch.2. Fuse Blown. Circuit

Page 7 - Vibration Isolators

Post Office Box 2510, Staunton, Virginia USA 24402 • (800) 432-1342 • www.mcquay.com

Page 8 - Water Piping

IOMM ACR/AGR-1 11Table 6, Ethylene Glycol FactorsFreeze Point%E.G.°F °CCapacity Power Flow Pressure Drop10 26 -3 0.991 0.996 1.013 1.07020 18 -8 0.982

Page 9 - Flow Switch

12 IOMM ACR/AGR-1Figure 7, Pressure Drop CurveNOMINAL MAXIMUM MINIMUMPD Flow PD Flow PD FlowCDESizeAGRUnitSizeft of Water gpm lps ft of Water gpm lps

Page 10 - Glycol Solutions

IOMM ACR/AGR-1 13Refrigerant PipingIntroductionProper refrigerant piping can represent the difference between a reliable, trouble free system andmonth

Page 11 - IOMM ACR/AGR-1 11

14 IOMM ACR/AGR-1Add b and c above to obtain the total equivalent feet. Use ASHRAE Table 3 (for R22) or Table 4 (forR134a). Suction line selections

Page 12 - Figure 7, Pressure Drop Curve

IOMM ACR/AGR-1 15Underground Refrigerant LinesMcQuay does not recommend the installation of suction lines underground. If job conditions requirethat

Page 13 - Refrigerant Piping

16 IOMM ACR/AGR-1totaling 10 x 3.05 psi (or 10 x 2.2) and still satisfy the objective of delivering solid liquid to theexpansion valve.In calculating

Page 14 - 14 IOMM ACR/AGR-1

IOMM ACR/AGR-1 17Physical DataAGR-AMTable 10, AGR 070AM - 085AMAGR MODEL NUMBERPHYSICAL DATASTANDARD EFFICIENCY070AM 075AM 080AM 085AMBASIC DATA Ckt.1

Page 15 - Liquid Lines

18 IOMM ACR/AGR-1Table 11, AGR 090AM - 100AMPHYSICAL DATA AGR MODEL NUMBERSTANDARD EFFICIENCY 090AM 095AM 100AMBASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.

Page 16 - Liquid Line Components

IOMM ACR/AGR-1 19Table 12, ACR 060AS - 070ASPHYSICAL DATA ACR MODEL NUMBERSTANDARD EFFICIENCY 060AS 065AS 070ASBASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.

Page 17 - Physical Data

2 IOMM ACR/AGR-1Table of ContentsIntroduction...3Inspection ...

Page 18 - Table 11, AGR 090AM - 100AM

20 IOMM ACR/AGR-1Table 13, ACR 075A - 090APHYSICAL DATA ACR MODEL NUMBERSTANDARD EFFICIENCY 075AS 080AS 090ASBASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1

Page 19 - Table 12, ACR 060AS - 070AS

IOMM ACR/AGR-1 21Table 14, ACR 100A - 120APHYSICAL DATA ACR MODEL NUMBERSTANDARD EFFICIENCY 100AS 110AS 120ASBASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1

Page 20 - Table 13, ACR 075A - 090A

22 IOMM ACR/AGR-1Electrical DataField WiringPower WiringCAUTIONInternal power wiring to the compressors for single and multiple point option arediffer

Page 21 - Table 14, ACR 100A - 120A

IOMM ACR/AGR-1 23AGR-AM DataACR DataTable 15, 60 Hz, Single Point Power Electrical DataPOWER SUPPLYField Wire Conduit HubACR-ASCond.UnitModelAGR-AMCh

Page 22 - Electrical Data

24 IOMM ACR/AGR-1Table 16, 60 Hz, Compressor & Condenser Fan Motor Amp Draw Rated LoadAmpsLocked Rotor AmpsCompressors CompressorsAcross-The-Line

Page 23 - ACR Data

IOMM ACR/AGR-1 25Table 17, 60 Hz Single Point Power, Field Wiring DataWiring to StandardPower BlockWiring to OptionalNon-Fused Disconnect SwitchACR-A

Page 24 - 24 IOMM ACR/AGR-1

26 IOMM ACR/AGR-1Electrical NotesNotes for “Electrical Data Single Point” Power:1. Unit wire size ampacity (MCA) is equal to 125% of the largest comp

Page 25 - IOMM ACR/AGR-1 25

IOMM ACR/AGR-1 27Electrical LegendFigure 8, Electrical Legend

Page 26 - Electrical Notes

28 IOMM ACR/AGR-1Wiring DiagramsFigure 9, AGR-AM, Typical Field Wiring with MicroTech Controller

Page 27 - Electrical Legend

IOMM ACR/AGR-1 29Figure 10, AGR-AM, Typical Field Wiring Diagram with UNT Controller

Page 28 - Wiring Diagrams

IOMM ACR/AGR-1 3IntroductionIMPORTANT INFORMATIONThis Product Manual contains information on three different McQuay product lines.• Model AGR-AM Th

Page 29 - IOMM ACR/AGR-1 29

30 IOMM ACR/AGR-1Figure 11, ACR-A, Field Wiring Diagram (No Capacity Control)

Page 30 - 30 IOMM ACR/AGR-1

IOMM ACR/AGR-1 31Figure 12, ACR-A, Field Wiring Diagram (Capacity Control Staging)

Page 31 - IOMM ACR/AGR-1 31

32 IOMM ACR/AGR-1Figure 13, AGR-AM, MicroTech Controller Schematic

Page 32 - 32 IOMM ACR/AGR-1

IOMM ACR/AGR-1 33Figure 14, AGR-AM, Unit Control Schematic (MicroTech)

Page 33 - IOMM ACR/AGR-1 33

34 IOMM ACR/AGR-1Figure 15, AGR-AM, Staging Schematic (MicroTech)

Page 34 - 34 IOMM ACR/AGR-1

IOMM ACR/AGR-1 35Dimensional DataFigure 16, Dimensions AGR 070AM and ACR 060AS -075ASACR AGR OVERALL COMPRESSOR # 1 (SUCTION #1) COMPRESSOR # 2 (SUCTI

Page 35 - Dimensional Data

36 IOMM ACR/AGR-1Figure 17, AGR 075AM - 100AM and ACR 080AS - 120ASCOMPRESSOR # 1 (SUCTION #1)inches (mm)COMPRESSOR # 2 (SUCTION #2)inches (mm)ACRMODE

Page 36 - 36 IOMM ACR/AGR-1

IOMM ACR/AGR-1 37CDE EvaporatorFigure 18, CDE 1004-1 - 1204-1WATER CONNECTIONinch (mm)REFRIGERANT CONNECTIONinch (mm)CDEMODELNUMBERC L P T M NCDE-120

Page 37 - CDE Evaporator

38 IOMM ACR/AGR-1StartupPre Start-upThe system components must be inspected to ensure that nothing has become loose or damagedduring shipping or insta

Page 38 - Shutdown

IOMM ACR/AGR-1 39Extended1. Front seat both condenser liquid line service valves.2. Put both circuit switches in Pumpdown and Stop position.3. Afte

Page 39 - Refrigerant Piping Checkout

4 IOMM ACR/AGR-1InstallationNote: Installation is to be performed by qualified personnel who are familiar with local codesand regulations.WARNINGSharp

Page 40 - Electrical Check Out

40 IOMM ACR/AGR-1Electrical Check OutCAUTIONElectrical power must be applied to the compressor crankcase heaters 24 hoursbefore starting unit.1. Open

Page 41 - Operation

IOMM ACR/AGR-1 41OperationHot Gas Bypass (Optional)This option allows the system to operate at low loads without the ON-OFF cycling of the compressor.

Page 42 - Crankcase Heaters

42 IOMM ACR/AGR-1System AdjustmentTo maintain peak performance at full load operation, the system superheat and liquid subcooling mayrequire adjustmen

Page 43 - Sequence of Operation

IOMM ACR/AGR-1 43DX EvaporatorThe evaporator is of the direct expansion type with removable internally finned tubes. The coppertubes are individually

Page 44 - 44 IOMM ACR/AGR-1

44 IOMM ACR/AGR-1Standard Controller Setpoints (optional Zone Terminal required tochange values)VALUESTEMPLATENAMEFACTORY SETPOINT RANGEOA/AI3 Lim SP

Page 45 - UNT Controller, AGR-AM

IOMM ACR/AGR-1 45UNT Controller, AGR-AMThe ACR Condensing Unit does not come factory equipped with a staging control. The control isfield supplied an

Page 46 - 46 IOMM ACR/AGR-1

46 IOMM ACR/AGR-1Unit Set Points and CalibrationThe control software is installed and tested by the factory before shipping. No periodic calibration

Page 47 - Controller Inputs /Outputs

IOMM ACR/AGR-1 47Chilled Water Flow SwitchThe chilled water flow switch is connected to field wiring terminals #142 and #143 on TB-7. When thechilled

Page 48 - Outside Air Reset

48 IOMM ACR/AGR-1Digital InputsNote: All Digital Inputs are 24Vac supplied by transformer T2 in the control panel. Do not useinputs from another powe

Page 49 - RWLL RWHL

IOMM ACR/AGR-1 49As the OAT increases above the Outdoor Air Low Limit (OALL), the Actual Leaving Water Setpoint isdecreased from its Leaving High Limi

Page 50 - ZTLL ZTHL

IOMM ACR/AGR-1 5LocationUnit PlacementAGR-AM and ACR units are for outdoor applications and can be mounted on a roof or ground level.Set units on a so

Page 51 - UNT Controller Features

50 IOMM ACR/AGR-1Figure 21, Zone Temperature ResetLWRBLWSPZTLL ZTHLZTRB(ZTLL=ZTHL - ZTRB)As the Zone Temperature increases above the Zone Temperature

Page 52 - Head Pressure Control

IOMM ACR/AGR-1 51Table 22, Dip Switch ConfigurationRemote Reset / Demand LimitGlobal UNT Dipswitch SettingsSwitch 1 2 3 4 5 6On (10V) X X X X XSW2Of

Page 53 - ZONE TERMINAL (optional)

52 IOMM ACR/AGR-1Pumpdown ControlThe AGR units have a one time pump down. The pump down is activated when a circuit’s liquid linesolenoid valve is de

Page 54 - OPERATING MODES

IOMM ACR/AGR-1 53AlarmsCircuit Alarm ConditionsThe “Circuit Alarm Conditions” are those alarms that only affect one circuit and can stop thecompressor

Page 55 - INSTALLING THE PLASTIC LABELS

54 IOMM ACR/AGR-1Figure 22, Zone TerminalMONITORADJUSTTIME SCHEDULEPASSWORD ENTERCompressor 1Compressor 2Stage 3Stage 4Solenoid #1Frzstat#1Al

Page 56 - 56 IOMM ACR/AGR-1

IOMM ACR/AGR-1 55DISPLAYS, SYMBOLS, KEYS, AND BUTTONSThe Zone Terminal simultaneously displays three set points or sensed values. In addition, flashi

Page 57 - Zone Terminal Glossary

56 IOMM ACR/AGR-1CONNECTING THE ZONE TERMINALYou can unit mount the ZT, or use it as a portable tool for convenient access to any chillerinformation.M

Page 58 - 58 IOMM ACR/AGR-1

IOMM ACR/AGR-1 57Adjustable PointsThe following McQuay Global Reciprocating Chiller points are adjustable by the Zone Terminal.Table 24, Adjustable Po

Page 59 - IOMM ACR/AGR-1 59

58 IOMM ACR/AGR-1Cir #2 Starts - Counts the number of starts for circuit #2. Note: If power is lost to the controller, thisdata is lost and will sta

Page 60 - 60 IOMM ACR/AGR-1

IOMM ACR/AGR-1 59Global UNT Controller Troubleshooting ChartPROBLEM POSSIBLE CAUSES CORRECTIVE ACTIONSCompressor will notrun1. Main switch, circuit b

Page 61 - MicroTech Controller

6 IOMM ACR/AGR-1Figure 3, Clearance RequirementsDo not block the flow of air toand from the condenser coil.Restricting airflow or allowingair recircul

Page 62 - Lead-Lag

60 IOMM ACR/AGR-14. Controller stage timing.5. Defective TXV.6. Hot gas bypass not set properly.7. Low ambient operation.4. Check timing and rese

Page 63 - IOMM ACR/AGR-1 63

IOMM ACR/AGR-1 61MicroTech ControllerAll operational descriptions are based on the MicroTech controller software versions rcp2e02g.cod forEnglish and

Page 64 - 64 IOMM ACR/AGR-1

62 IOMM ACR/AGR-1Interlock wiringThe installing contractor provides all interlock wiring to field devices (such as flow switches andpump starters). S

Page 65

IOMM ACR/AGR-1 63Field WiringInterconnecting wiring for the control panel may consist of the following:• 115Vac power wiring• Chilled water pump rel

Page 66

64 IOMM ACR/AGR-1Digital OutputsThe digital output board has normally open solid-state relays with an on-board replaceable 5 ampfuse. The status of a

Page 67 - Soft Loading

IOMM ACR/AGR-1 65Controller Inputs /OutputsAnalog InputsAnalog inputs are used to read the various temperatures and pressures on the chiller as well a

Page 68 - Safety Systems

66 IOMM ACR/AGR-1Table 27, Relay Board OutputsDigital OutputNumberOutputDescription0 Alarm Circuit1 Chilled Water Pump Relay2 Liquid Line Solenoid Ci

Page 69 - System Alarm Conditions

IOMM ACR/AGR-1 67The remote 4-20mA input must be 4mA or less and the leaving water temperature will be controlled tothe calculated setpoint. When the

Page 70

68 IOMM ACR/AGR-1Manual OperationManual operating modes are available to simplify setup and troubleshooting of the unit. Any of thefollowing manual m

Page 71 - Pumpdown

IOMM ACR/AGR-1 69The MicroTech controller alarms can either be of the manual reset type or the auto reset type. Criticalalarm conditions such as High

Page 72 - Start-Up and Shutdown

IOMM ACR/AGR-1 7Vibration IsolatorsVibration isolators are recommended for all roof mounted installations or wherever vibrationtransmission is a consi

Page 73 - Keypad / Display

70 IOMM ACR/AGR-1Sequence of OperationOff ConditionsWith power supplied to the unit, 115Vac power is applied through the control fuse F1 to thecompres

Page 74 - Password Information

IOMM ACR/AGR-1 71Low Ambient StartIf the “LOW AMBIENT” option was selected and the out side air temperature is below 50°F, the lowambient start logic

Page 75 - Keypad Key Functions

72 IOMM ACR/AGR-1Start-Up and ShutdownPre-Start CheckoutConfiguration default set points are entered at the factory and all values must be checked and

Page 76 - Menu Descriptions

IOMM ACR/AGR-1 73Move both pumpdown switches to the auto position. DH1-7 and DH2-15 will turn off. The controllerwill then activate one of the refri

Page 77 - Control Menus

74 IOMM ACR/AGR-1Menu Structure (General Description)The information stored in the MicroTech controller can be accessed through the keypad using a tre

Page 78

IOMM ACR/AGR-1 75Keypad Key FunctionsThe MicroTech keypad consists of twelve pressure sensitive membrane switches (refer to Figure 25).These keys are

Page 79 - IOMM ACR/AGR-1 79

76 IOMM ACR/AGR-1Decr.When changing the value of a menu item entry, pressing “DECR. -” shifts the menu itemdisplay line to the next lower value or pr

Page 80 - Alarm Menus

IOMM ACR/AGR-1 77Menu #6: Circuit 62 PressuresThe circuit #2 evaporator and condenser refrigerant pressurereadings are displayed under this menu. The

Page 81 - IOMM ACR/AGR-1 81

78 IOMM ACR/AGR-1If the 4-20 milliamp reset option is enabled, the controller will reset the leaving chilled watertemperature to a higher value based

Page 82 - 82 IOMM ACR/AGR-1

IOMM ACR/AGR-1 79Figure 26, Delta-T Setpoints for ChillersMenu #15: Softload Set Points—The controller can limit the number of available stages when t

Page 83 - IOMM ACR/AGR-1 83

8 IOMM ACR/AGR-1Table 3, AGR-AM Isolator Loads At Each Mounting Location With Copper Fins1 2 3 4 TOTAL UNITAGR-AMSizelb kg lb kg lb kg lb kg lb kg070

Page 84 - 84 IOMM ACR/AGR-1

80 IOMM ACR/AGR-1Press the Next Item key. The display will show the current Day, Hour, Minute and Second. If thisinformation needs to be changed, foll

Page 85 - Table 53, MENU 22 Alarm Spts

IOMM ACR/AGR-1 81Table 29, MENU 1 Chiller StatusScreen DisplayOFF: Manual ModeOFF: System SwOFF: Remote CommOFF: Remote SwOFF: Time ClockOFF: AlarmOF

Page 86 - Table 54, MENU 23 Misc Setup

82 IOMM ACR/AGR-1Table 35, MENU 7 Circ #1 Temp'sScreen DisplaySatur Evap=xxx°F (°C)1N/A **°F (°C)SuctLine = xxx.x°F (°C)Open °F (°C)2Short °F (°C

Page 87 - IOMM ACR/AGR-1 87

IOMM ACR/AGR-1 83Table 41, MENU 13 Control ModeScreen Display Factory Setpoint RangeManual Unit OffAutomaticManual Staging1 Manual Unit Off2 Manual St

Page 88 - Hex Switches

84 IOMM ACR/AGR-1Table 44, MENU 15 SoftLoad SptsScreen Display Factory Setpoint Range1 Time Left= xxmin2 SoftLoad= xx min 20 0 - 2543 SoftLdMaxStg= x

Page 89 - IOMM ACR/AGR-1 89

IOMM ACR/AGR-1 85Table 50, MENU 20 ScheduleScreen Display Factory Setpoint Range1 Override= xx.xx hr 0.00 Hr 00:00 - 63.502 NMPSchedule= N/A N/A3 Sun

Page 90 - Test Procedures

86 IOMM ACR/AGR-1Table 54, MENU 23 Misc SetupScreen Display Factory Setpoint Range1 Unit Type= Air Cooled - -2 Model AGZ 4 Stages - -3 # Compressors

Page 91 - IOMM ACR/AGR-1 91

IOMM ACR/AGR-1 87MicroTech Controller Trouble AnalysisMicroprocessor Control BoardThe Microprocessor Control Board (MCB) is shown in Figure 27. It con

Page 92 - 92 IOMM ACR/AGR-1

88 IOMM ACR/AGR-1Following is the normal start-up sequence that the three status LED’s should follow when power isapplied to the MCB:1. The red (“Res

Page 93 - Troubleshooting Output Boards

IOMM ACR/AGR-1 89Figure 28, Hex Switches1230456789ABCDEF1230456789ABCDEFHI (left) hex switch LO (right) hex switch* Hex switch setting 01 shownCommuni

Page 94 - 94 IOMM ACR/AGR-1

IOMM ACR/AGR-1 99. If the unit is used as a replacement chiller on a previously existing piping system, flush thesystem thoroughly before unit instal

Page 95 - Contact Chatter

90 IOMM ACR/AGR-1Test ProceduresStatus LED DiagnosticsThe MCB status LED indications can aid in controller diagnostics. If the status LEDs do not oper

Page 96 - 96 IOMM ACR/AGR-1

IOMM ACR/AGR-1 916. Reconnect the analog input ribbon cable. Cycle power to the controller and check the powerfuses.If both fuses are intact, go to s

Page 97 - Unit Maintenance

92 IOMM ACR/AGR-1Figure 29, MCB Power Supply TerminalsPOWER FUSES[BUSSMAN GDC-T2A]POWER IN[18-24 VCT]AC AC GND GNDAUX/OUT43219 8 7 6 5 4 3 2 1Fuse F1F

Page 98 - 98 IOMM ACR/AGR-1

IOMM ACR/AGR-1 93Troubleshooting Analog InputsAn analog input, such as a temperature sensor, is connected to the ADI board. The ADI board thenconditi

Page 99 - Liquid Line Solenoid Valve

94 IOMM ACR/AGR-1Figure 30, Output Board Relay Socket12345LEDFuseTest Resistor330-680 Ohm*250V ~ 50/60 Hz*120V ~ 50/60 HzWARNINGElectric shock hazard.

Page 100 - Refrigerant Charging

IOMM ACR/AGR-1 952. Remove power from the controller by placing CB1 to the OFF position. Disconnect at least onewire from the power input terminals

Page 101 - IOMM ACR/AGR-1 101

96 IOMM ACR/AGR-13. Remove power from the controller by opening CB1. Try to improve the connections in theAux/Out plug insulation displacement termi

Page 102 - AGR Troubleshooting Chart

IOMM ACR/AGR-1 97Unit MaintenanceGeneralOn initial start-up and periodically during operation, it will be necessary to perform certain routineservice

Page 103

98 IOMM ACR/AGR-115°F) and flashing is visible in the sightglass check the pressure drop across the filter-drier.Subcooling should be checked at full

Page 104

IOMM ACR/AGR-1 99ServiceCAUTION1. Service on this equipment is to be performed by qualified refrigeration personnelfamiliar with equipment operation,

Comments to this Manuals

No comments