Possible Opening Dimension For Duct Connection
Air Discharge Knock Out Hole
Air Intake Knock Out Hole
NOTE
Avoid using the short duct on which the air discharge grille can be completely closed, to prevent evaporator freezing.
In order to prevent condensation forming, be sure that there is sufficient thermal insulation and no leakage of cool
air when installing the short duct.
Keep the introduction of fresh air intake within 20% of total air flow. Also provide a chamber and use a booster fan.
Sealing Material
It is possible to seal one of the four air discharge outlet. (sealing two or more air discharge outlet could cause a malfunction)
Remove the front panel and insert the sealing material into the air discharge outlet on the indoor unit to seal the air outlet.
The sealing material is the same length as the longer air discharge outlet. If it is desired to seal the shorter air discharge
outlet, cut the sealing material to shorten it.
Push the sealing material in about 10 mm beyond the bottom surface of the indoor unit so that it does not touch the air
louver. Be sure not to push the sealing material in any farther than about 10 mm.
INDICATOR LIGHTS
Remote Control
When there is infrared remote control operating signal, the signal receiver on indoor unit will make a <beep> for signal
acceptance confirmation.
Operating State And Fault Table
Wireless Remote Control
COOLING HEAT PUMP
POWER TIMER SLEEP POWER TIMER HEAT OPERATION / FAULTY INDICATION ACTION
/ / / / Power ON -
Room/Indoor/Outdoor (heat pump) Coil Call Your Dealer
Sensor Contact Loose/Short
Gas Leak Faulty/Compressor Overload Call Your Dealer
Condensate Water Overflow Call Your Dealer
Outdoor Defrost (heat pump only)
10
50 50 50 50 50 10
207020109
119 90
fl100
PCD fl140
115 20 115
COOLING HEAT PUMP
HMLCSTHMLCSTH OPERATION / FAULTY ACTION
I E O O L I I E O O L I E INDICATION
GDWOEMGDWOEMA
H LEEH LEET
PR PR
Room Sensor Contact Loose/Short Call Your Dealer
Indoor Coil Sensor Contact Loose/Short Call Your Dealer
Outdoor Coil Sensor Contact Loose/Short Call Your Dealer
Gas Leak Faulty Call Your Dealer
Compressor Overload Call Your Dealer
Condensate Water Overflow Call Your Dealer
Outdoor Defrost (heat pump only) Call Your Dealer